Effect of cement dosage and waste tire rubber on the mechanical, transport and abrasion characteristics of foam concretes subjected to H2SO4 and freeze–thaw       
Yazarlar
Doç. Dr. Oğuzhan Yavuz BAYRAKTAR Doç. Dr. Oğuzhan Yavuz BAYRAKTAR
Kastamonu Üniversitesi, Türkiye
Hasan Söylemez
Gökhan Kaplan
Atatürk Üniversitesi, Türkiye
Ahmet Benli
Bingöl Üniversitesi, Türkiye
Osman Gençel
Bartın Üniversitesi, Türkiye
Mesut Türkoğlu
Özet
This paper presents an experimental study of the effects of cement dosage and waste tire rubber as aggregate on the mechanical, transport and abrasion characteristics of foam concretes subjected to H2SO4 and freeze–thaw cycles. Foam concrete mixtures were made with two percentages 0, and 20 of silica fume (SF) as partial substitution of Portland cement (PC) and with 100% of waste tire rubber (WRA) as substitution of fine aggregates. Two groups of mixtures were prepared with SF contents of 0% and 20%. At each group of mixtures, three cement contents of 300, 400 and 500 kg/m3 and three foam contents of 20, 40 and 60 kg/m3 were used to produce concretes mixtures having water/binder (w/b) ratio of 0.75. Workability of fresh concretes were assessed by performing slump test. Compressive and flexural strength of the mixtures were determined after 7 and 28 days and transport properties were measured by means of porosity and water absorption after 28 days. Tests for shrinkage, sorptivity, abrasion, acid attack and freeze–thaw cycles of 30 and 60 were also performed in addition to microstructure investigations. An optimization was also performed. The results exhibited that increase in cement dosage resulted in the compressive strength by 204.50% maximum increment at cement content of 500 kg/m3 as compared to the mixture with dosage of 300 kg/m3 at foam content of 20 kg/m3. Based on the results, it was concluded that the lowest and highest shrinkage values of 5032 × 10−6 and 7065 × 10-6 mm/mm were gained for the mixtures with cement dosages of 300 kg/m3 and 500 kg/m3 and foam content of 20 kg/m3 respectively. The results also indicated that SF blended mixture with cement content of 500 kg/m3 foam content of 20 kg/m3 showed the best resistance after abrasion, F-T cycles and acid attack exposure.
Anahtar Kelimeler
Foam concrete | Freeze–thaw cycles | Physical and mechanical properties | Sulphuric acid | Waste tire rubber
Makale Türü Özgün Makale
Makale Alt Türü SSCI, AHCI, SCI, SCI-Exp dergilerinde yayımlanan tam makale
Dergi Adı CONSTRUCTION AND BUILDING MATERIALS
Dergi ISSN 0950-0618
Dergi Tarandığı Indeksler SCI-Expanded
Dergi Grubu Q1
Makale Dili İngilizce
Basım Tarihi 10-2021
Cilt No 302
Sayı 124229
Doi Numarası 10.1016/j.conbuildmat.2021.124229
Makale Linki http://dx.doi.org/10.1016/j.conbuildmat.2021.124229