img
Extracorporeal Circulation and Optic Nerve Ultrasound: A Pilot Study      
Yazarlar
Doç. Dr. Öztürk TAŞKIN Doç. Dr. Öztürk TAŞKIN
Kastamonu Üniversitesi, Türkiye
Doç. Dr. Ufuk DEMİR Doç. Dr. Ufuk DEMİR
Kastamonu Üniversitesi, Türkiye
Özet
Background and Objectives: Cardiopulmonary bypass (CPB) is an extracorporeal circuit that provides surgical access to an immobile and bloodless area, allowing for technical and procedural advances in cardiothoracic surgery. CBP can alter the integrity of the blood–brain barrier and cause changes in intracranial pressure (ICP) postoperatively. Optical nerve sheath diameter (ONSD) measurement is among the alternative non-invasive methods for ICP monitoring. In this study, we aimed to evaluate the optic nerve sheath diameter measurements under the guidance of ultrasonography for ICP changes during the extracorporeal circulation process. Materials and Methods: The study population included 21 patients over 18 years of age who required extracorporeal circulation. Demographic data of the patients, such as age, gender, comorbidity, American Society of Anesthesiologists (ASA) classification and reason for operation (coronary artery disease or mitral or aortic valve disease) were recorded. The ONSD was measured and evaluated before the extracorporeal circulation (first time) and at the 30th minute (second time), 60th minute (third time) and 90th minute (fourth time) of the extracorporeal circulation. Non-invasive ICP (ICP ONSD) values were calculated based on the ONSD values found. Results: The mean ONSD values measured before the extracorporeal circulation of the patients were found to be 4.13 mm (3.8–4.6) for the right eye and 4.36 mm (4.1–4.7) for the left eye. Calculated nICPONSD values of 11.0 mm Hg (1.0–21.0) for the right eye and 10.89 mm Hg (1.0–21.0) for the left eye were found. It was observed that there was a significant increase in the ONSD and nlCPONSD values recorded during the extracorporeal circulation of all patients compared to the baseline values (p < 0.005). Conclusions: During extracorporeal circulation, ultrasound-guided ONSD measurement is an easy, inexpensive and low-complication method that can be performed at the bedside during the operation to monitor ICP changes.
Anahtar Kelimeler
cardiopulmonary bypass | extracorporeal circuit | intracranial pressure | optical nerve sheath diameter
Makale Türü Özgün Makale
Makale Alt Türü SSCI, AHCI, SCI, SCI-Exp dergilerinde yayımlanan tam makale
Dergi Adı MEDICINA-LITHUANIA
Dergi ISSN 1648-9144
Dergi Tarandığı Indeksler SCI-Expanded
Dergi Grubu Q1
Makale Dili Türkçe
Basım Tarihi 02-2023
Cilt No 59
Sayı 3
Sayfalar 445 / 0
Doi Numarası 10.3390/medicina59030445
Makale Linki http://dx.doi.org/10.3390/medicina59030445
BM Sürdürülebilir Kalkınma Amaçları
Atıf Sayıları
SCOPUS 1
Google Scholar 1
Extracorporeal Circulation and Optic Nerve Ultrasound: A Pilot Study

Paylaş