Evaluation of the Freestyle Optium Neo H point‐of‐care device for measuring blood glucose concentrations in sick calves
 
Yazarlar (3)
Prof. Dr. Tolga Karapınar Fırat Üniversitesi, Türkiye
Doç. Dr. Kenan Çağrı TÜMER Fırat Üniversitesi, Türkiye
Sebastien Buczinski
University Of Montreal, Kanada
Makale Türü Açık Erişim Özgün Makale (SSCI, AHCI, SCI, SCI-Exp dergilerinde yayınlanan tam makale)
Dergi Adı Journal of Veterinary Internal Medicine (Q1)
Dergi ISSN 0891-6640 Wos Dergi Scopus Dergi
Dergi Tarandığı Indeksler SCI-Expanded
Makale Dili İngilizce Basım Tarihi 04-2020
Cilt / Sayı / Sayfa 34 / 4 / 1650–1656 DOI 10.1111/jvim.15794
Makale Linki https://onlinelibrary.wiley.com/doi/full/10.1111/jvim.15794
Özet
Background Data on the performance of a glucometer in calves with different diseases are currently lacking. Objective The primary objective of this study was to evaluate the reliability of a point of care glucometer in calves affected by different diseases relative to a traditional bench-top autoanalyzer. Animals One hundred ninety-six calves with different disorders in a referral hospital. Methods Prospective study. Venous blood samples were used for the determination of glucose concentrations in blood and plasma using the Freestyle Optium Neo H and autoanalyzer, respectively. Data were subjected to Passing-Bablok regression and Bland-Altman plots. The Freestyle Optium Neo H was the test method and the autoanalyzer was the reference method. The diagnostic performance of the glucometer relative to the autoanalyzer was …
Anahtar Kelimeler
accuracy | bovine | glucometer | precision | sensitivity | specificity
BM Sürdürülebilir Kalkınma Amaçları
Atıf Sayıları
Web of Science 9
Scopus 11
Google Scholar 12
Evaluation of the Freestyle Optium Neo H point‐of‐care device for measuring blood glucose concentrations in sick calves

Paylaş