| Makale Türü |
|
||
| Dergi Adı | Turkiye Klinikleri Journal of Medical Sciences | ||
| Dergi ISSN | 1300-0292 Dergi Bilgileri (2013) | ||
| Dergi Tarandığı Indeksler | EMBASE, Scopus, EBSCO/CINAHL, Chemical Abstracts Service (CAS), ProQuest, Turkiye Citiation Index, Turkiye Klinikleri Medical Database | ||
| Makale Dili | İngilizce | Basım Tarihi | 01-2013 |
| Kabul Tarihi | – | Yayınlanma Tarihi | 01-01-2013 |
| Cilt / Sayı / Sayfa | 33 / 2 / 455–463 | DOI | 10.5336/medsci.2012-30139 |
| Makale Linki | http://www.tipbilimleri.turkiyeklinikleri.com/abstract_64452.html | ||
| UAK Araştırma Alanları |
Göz Hastalıkları
|
||
| Özet |
| Objective To evaluate the relationship between tear osmolarity, Ocular Surface Disease Index (OSDI© Allergan Inc., Irvine, Calif), Schirmer test and tear break-up time (TBUT). Material and Methods After performing Ocular Surface Disease Index (OSDI©) survey, tear osmolarity testing with TearLab osmolarity system, Schirmer test without anesthesia and TBUT measurement were performed in 40 patients with dry eye syndrome diagnosis and 39 healthy subjects. Student t-test and Spearman's rho correlation analysis are used for statistical evaluation. Results The mean tear osmolarity was 307±19.2 mOsm/l in group A, while it was 292.9±13.9 mOsm/l in group B. Schirmer test results were in normal ranges in both groups (13.4±7.5 mm in group A, and 17.4±8.5 mm in group B). TBUT was lower in group A, and the difference between two groups was statistically significant. OSDI© scoring was 43.9±20.4 in group A, while it was 8.56±5.2 in group B and the difference was statistically significant. The sensitivity and spesificity of tear osmolarity for threshold value 305 mOsm/l were found to be 76.9% and 80%, for TBUT for 10 seconds were 94.7% and 71.8%; for OSDI© score> 15 were 79.5% and 70% and for Schirmer's test for 10 mm were 35.9% and 80%. Conclusion Of all tests, TBUT, tear osmolarity and OSDI© are found to be successful in discriminating dry eye patients from healthy participants. The specificity and the sensitivity of the commonly used Schirmer test are found to be low.© 2013 by Türkiye Klinikleri. |
| Anahtar Kelimeler |
| Diagnostic tests | Dry eye syndromes | Osmolar concentration | Routine | Sensitivity and specificity | Tears |
| Atıf Sayıları | |
| Scopus | 2 |
| Google Scholar | 4 |
| Dergi Adı | TURKIYE KLINIKLERI JOURNAL OF MEDICAL SCIENCES |
| Kısa Adı | |
| Yayıncı | Turkiye Klinikleri |
| Açık Erişim | Hayır |
| ISSN | 1300-0292 |
| Scopus Quartile | Q3 |
| Tarandığı Indeksler | Scopus |
| WoS Kategoriler | |
| Scopus Kategoriler | MEDICINE (MISCELLANEOUS) |